jaguar Workshop Repair Guides

Jaguar Workshop Service and Repair Manuals

Left-Hand|Page 1652 > < Left-Hand|Page 1650
Page 3
background image

Remove the bolts which secure the downpipe lower mounting bracket.
Remove the downpipe assembly.

9. Remove gasket from the manifold flange.

Clean and inspect the manifold joint faces.
Clean and inspect the threads on the down pipe studs.

Installation

1. Fit a new gasket to the manifold mating flange on the down pipe.

2. Fit the downpipe catalytic converter.

Fit the downpipe assembly to the manifold
Fit, but do not fully tighten, the mounting bracket securing bolts. (Leave loose until the nuts securing the downpipe to the exhaust manifold are
fitted.)

3. Lower the ramp.

4. Tighten the nuts securing the downpipe flange to the manifold flange.

Left-Hand|Page 1652 > < Left-Hand|Page 1650