X-Type (X400) V6-3.0L (2002)
12.
Remove and discard the two pinion housing securing bolts (Illustration 9)
Caution:
Make sure the working surfaces are thoroughly clean to avoid contamination of the sensitive hydraulic components. Before the disconnection
or removal of any components, ensure the area around joint faces and connections are clean. Plug any open connections to prevent
contamination.
Note:
On removal the pinion shaft will rotate approximately 90 degrees counterclockwise.
13.
Using a nylon mallet, carefully release the pinion housing.
14.
Place the pinion housing assembly in a clean plastic bag, and seal to prevent contamination.
Caution:
It is imperative that no damage is caused to the seal register when removing the seal. Protect the seal register using lint free cloth.