WARRANTY

REPAIR PROCEDURE

RECONFIGURE INSTRUMENT CLUSTER CONTROL MODULE

1. Verify instrument cluster speaker operates correctly and the sound is not distorted.

^

If the speaker is inoperative, diagnose and repair as a separate Warranty claim. In the event the instrument cluster is replaced, ensure this Recall
action is 'closed' in DDW.

^

If the speaker operates normally, proceed to step 2.

CAUTION:

A Midtronics PSC-550 Vehicle Power Supply must be connected to the vehicle battery during diagnosis / module programming.

2. Connect the Midtronics PSC-550 Vehicle Power Supply to the vehicle battery.

NOTE:

IDS must be loaded with software release DVD115 Patch File 4 or later.

3. Connect the IDS to the vehicle and begin a new diagnostic session by entering the correct VIN for the current vehicle.

4. Follow the IDS prompts to read the vehicle configuration.

5. Select 'No' when prompted 'Do you wish to read diagnostic trouble codes?'

6. Select 'tick' to continue.

7. Select the 'Vehicle Configuration' tab when Content Model is displayed.

8. From the Vehicle Configuration menu, configure the 'Instrument cluster control module' by selecting from the drop-down menu:

^

'Module programming' > 'Configure existing module' > 'Instrument cluster control module'

9. Select 'tick' to continue, following all on-screen instructions to complete this task.

^

IDS will return to the Vehicle Configuration menu when completed

10. Exit the current session.