XJ-6 L6-4.2L (1983)
![background image](/jaguar/xj-6/l6-4.2l/Page-63001.png)
Ambient Temperature Sensor / Switch HVAC: Testing and Inspection
Ambient Temperature Sensor
Ambient Temperature Sensor
Testing:
Suggest best method of testing is by substitution. Resistance should be no greater than 3.9K ohms.