jaguar Workshop Repair Guides

Jaguar Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC|Description and Operation|Page 6330 > < Refrigerant Oil|Capacity Specifications|Page 6326
Page 1
background image

Refrigerant Pressure Sensor / Switch: Description and Operation

Pressure Cut Off Switch

The pressure cut off switch monitors the A/C compressor discharge pressure and communicates with the engine control module (ECM). The ECM will
interrupt A/C compressor operation in the event that the pressure cut off switch indicates high system discharge pressures. It is also used to sense no or
low charge conditions. If the pressure is below a predetermined value for a given ambient temperature, the ECM will interrupt A/C compressor
operation.

-

The pressure cut off switch is mounted on a Schrader-type valve fitting on the compressor to condenser discharge line.

-

A valve depressor, located inside the threaded end of the pressure cut off switch, presses on the Schrader valve stem and allows the pressure cut
off switch to monitor the compressor discharge pressure.

-

When the compressor discharge pressure rises to approximately 2,896 kPa (420 psi), the ECM will interrupt the compressor operation and disable
the compressor.

-

When the pressure drops to approximately 1,724 kPa (250 psi) the ECM will enable the A/C compressor circuit.

Refrigerant Pressure Sensor / Switch, HVAC|Description and Operation|Page 6330 > < Refrigerant Oil|Capacity Specifications|Page 6326