XJR (X300) L6-4.0L SC (AJ16) (1995)
Drive Belt: Adjustments
Drive Belt, Alternator
Generator/Water Pump Drive Belt
Burroughs method: new belt 560 to 600 N. Run for one minute, allow belt to cool and reset to the in-service setting. If in-service tension falls below
335 N, reset at 405 N to 445 N.
Clavis method: new belt 180 to 186 Hz. Run for one minute, allow belt to cool and reset to the in -service setting. If the in-service tension falls below
131 Hz, reset at 155 to 161 Hz. (Measuring point: mid-way between crankshaft and generator pulleys).