XJR (X308) V8-4.0L SC (AJ26) (1998)
manufacturer's instructions and depressurize the fuel system.
5. Store the drained fuel safely and ensure that the lid is closed securely. Remove the equipment and discard the cloth from beneath the valve. Refit
the valve cap.
6. Drain the radiator coolant.
7. Disconnect the breather pipe from Bank 1 camshaft cover.
Disconnect the breather pipe from the stub pipe.
Remove and discard the O-ring seal from the breather pipe.
8. Disconnect the air flow meter multi-plug.
9. Cut and remove the strap, which secures the vacuum pipe to the induction elbow.
10. Disconnect the intake tube from the throttle body.
Remove the two bolts, which secure the intake tube to the throttle body.
Disconnect the intake tube from the throttle body.
11. Disconnect the air cleaner cover.
Remove the five clips, which secure the air cleaner cover.