4. Connect the fuel injection pressure test equipment 310-058 (or other suitable type).
Insert the drain/bleed tube into the fuel container. Follow the manufacturer's instructions and depressurize the fuel system.
5. Store the drained fuel safely and ensure that the lid is closed securely. Remove the equipment and discard the cloth from beneath the valve. Install
the valve cap.
6. Open the driver's door, or both doors if necessary, to allow the side glass to drop.
Ensure that the doors remain open until after the battery has been disconnected.
7. Disconnect the battery ground cable.
Remove the battery cover.
8. Disconnect the breather pipe from Bank 1 camshaft cover.
Disconnect the breather pipe from the stub pipe.
Remove and discard the O-ring seal from the breather pipe.
9. Disconnect the air flow meter multi-plug.
10. Cut and remove the strap which secures the vacuum pipe to the induction elbow.