Variable Valve Timing Solenoid: Service and Repair

Variable Camshaft Timing (VCT) Oil Control Solenoid (18.30.90)

Removal

NOTE:  Removal of the RH is similar to this procedure.

1. Remove the cover and disconnect the battery ground cable.
2. Remove the LH valve cover.
3. Remove the VCT oil control solenoid.

-

Remove the bolt.

Installation

1. Install the VCT oil control solenoid.

-

Clean the components.

-

Tighten the bolt to 10 Nm (7 lb.ft).

2. Install the LH valve cover.
3. Connect the battery ground cable and install the cover.