jaguar Workshop Repair Guides

Jaguar Workshop Service and Repair Manuals

Control Assembly, HVAC|Description and Operation|Page 3025 > < Control Assembly, HVAC|Description and Operation|Page 3023
Page 3
background image

-

The first two conditions exist > 2 minutes.

-

Engine speed > 50 revs/min

14. Heated Backlight (R)

Pressing the heated backlight button will simultaneously energize the heater elements for timed cycles of;
-

21 minutes backlight

-

11 minutes exterior mirrors

Pressing the button again within the 21 minute timer will cancel the request.

If the engine is stalled, or the ignition switched OFF, the backlight and door mirror timers will be cleared, resulting in both functions being
switched off.

NOTE:  Both the backlight and door mirrors may be activated with the climate control system OFF, but the engine must be running.

15. Temperature Decrease

Pressing this button (BLUE symbol) decreases the interior temperature setting in  increments. Should the button be pressed when the setting
temperature is below the lower automatic control temperature limit, the display will indicate 'LO'.

16. Temperature Increase

Pressing this button (RED symbol) will raise the temperature setting in  increments Should the button be pressed when the setting temperature is
above the upper automatic control temperature limit, the display will indicate 'HI'.

Automatic Temperature Control Range
°C

°F

LO

LO

17

61
62

18

63
64

19

65
66

20

67
68

21

69
70

22

71
72

23

73
74

24

75
76

25

77
78

26

79
80

27

81
82

28

83
84

29

85
86

30

87
88

31

89
90

HI

HI

LO demands the maximum COOLING performance from the system with the blowers operating automatically at maximum speed.

HI demands the maximum HEATING performance from the system with the blowers operating automatically at maximum speed.

Pressing and holding either temperature selection button continuously changes the setting temperature by steps of , every 0.4 seconds.

NOTE:  The interior temperature does not change when the temperature scale is changed between Celsius and Fahrenheit, however the
temperature display will change to the nearest equivalent number.