jeep Workshop Repair Guides

Jeep Workshop Service and Repair Manuals

Drive Belts, Mounts, Brackets and Accessories > < Valve, Intake/Exhaust|Removal and Installation|Page 1269
Page 2
background image

3. Insert a telescoping gauge into the valve stem guide bore approximately 9.825 mm (0.375 inch) from the valve spring side of the head (Fig. 19).
4. Remove and measure telescoping gauge with a micrometer.
5. Repeat the measurement with contacts lengthwise to engine cylinder head.
6. Compare the crosswise to lengthwise measurements to determine out-of-roundness. If the measurements differ by more than 0.0635 mm (0.0025

inch), ream the guide bore to accommodate an oversize valve stem.

7. Compare the measured valve guide bore diameter with specifications (7.95 - 7.97 mm or 0.313 - 0.314 inch). If the measurement differs from

specification by more than 0.076 mm (0.003 inch), ream the guide bore to accommodate an oversize valve stem.

ALTERNATIVE METHOD 

1. Use a dial indicator to measure the lateral movement of the valve stem (stem-to-guide clearance). This must be done with the valve installed in its

guide and just off the valve seat (Fig. 20).

2. Correct clearance is 0.025 - 0.0762 mm (0.001 - 0.003 inch). If indicated movement exceeds the specification ream the valve guide to

accommodate an oversize valve stem.

NOTE:  Valve seats must be ground after reaming the valve guides to ensure that the valve seat is concentric to the valve guide.

Drive Belts, Mounts, Brackets and Accessories > < Valve, Intake/Exhaust|Removal and Installation|Page 1269