jeep Workshop Repair Guides

Jeep Workshop Service and Repair Manuals

Isolating Compressor|Page 3611 > < A/C Suction Line - Growling Noise
Page 1
background image

Compressor HVAC: Service and Repair
Isolating Compressor

Fig. 1  Cross-Sectional View Of Compressor Service Valves

1.

Connect suitable gauge manifold to system and remove protective caps from manual valve stems.

2.

Slightly open both service valves toward mid-position, then start engine and operate air conditioning.

3.

Slowly rotate suction (low) side service valve clockwise toward front-seated position.

4.

When suction (low) side gauge reads zero, stop engine, then rotate both low and high side valves to the fully clockwise (front-seated) position.

5.

Relieve internal compressor pressure on Sankyo 5 cylinder and York 2 cylinder compressors, by slightly loosening the oil sump filler plug. A
suitable face shield should be worn when relieving compressor pressure.

Isolating Compressor|Page 3611 > < A/C Suction Line - Growling Noise