Commander 2WD V6-3.7L (2009)
3. Install the three screws (4) that secure the recirculation door actuator (2) to the HVAC air inlet housing (3). Tighten the screws to 2 Nm (17 in.
lbs.).
4. Connect the HVAC wire harness connector (1) to the recirculation door actuator.
5. Install the glove box into the instrument panel See: Body and Frame/Interior Moulding / Trim/Glove Compartment/Service and Repair/Instrument
Panel Glove Box - Installation.
6. Reconnect the negative battery cable.
7. Initiate the Actuator Calibration function using a scan tool . See: Testing and Inspection/Component Tests and General Diagnostics/HVAC
System Test