Positive Crankcase Ventilation Valve: Service and Repair

REMOVAL

The PCV valve (6) is located on the oil filler tube (4). Two locating tabs are located on the side of the valve (2). These 2 tabs fit into a cam lock (3) in
the oil filler tube. An O-ring (1) seals the valve to the filler tube.

1. Disconnect PCV line/hose (5) by disconnecting rubber hose at PCV valve fitting.
2. Remove PCV valve at oil filler tube by rotating PCV valve downward (counter-clockwise) until locating tabs (2) have been freed at cam lock (3).

After tabs have cleared, pull valve straight out from filler tube. To prevent damage to PCV valve locating tabs, valve must be pointed downward
for removal. Do not force valve from oil filler tube.

3. After valve is removed, check condition of valve O-ring (1).

INSTALLATION

The PCV valve is located on the oil filler tube. Two locating tabs are located on the side of the valve. These 2 tabs fit into a cam lock in the oil filler
tube. An O-ring seals the valve to the filler tube.

1. Return PCV valve back to oil filler tube by placing valve locating tabs into cam lock. Press PCV valve in and rotate valve upward. A slight click

will be felt when tabs have engaged cam lock. Valve should be pointed towards rear of vehicle.

2. Connect PCV line/hose and rubber hose to PCV valve.