jeep Workshop Repair Guides

Jeep Workshop Service and Repair Manuals

Blower Motor Diagnosis and Testing|Page 6990 > < Automatic Temperature Control|Page 6987
Page 1
background image

Blower Motor: Testing and Inspection
Blower Motor Diagnosis and Testing

WARNING:  ON VEHICLES EQUIPPED WITH AIRBAGS, REFER TO AIRBAGS SYSTEMS BEFORE ATTEMPTING ANY STEERING
WHEEL, STEERING COLUMN, OR INSTRUMENT PANEL COMPONENT DIAGNOSIS OR SERVICE. FAILURE TO TAKE THE
PROPER PRECAUTIONS COULD RESULT IN ACCIDENTAL AIR-BAG DEPLOYMENT AND POSSIBLE PERSONAL INJURY
.

BLOWER MOTOR

Possible causes of an inoperative blower motor include:

Faulty fuse

Faulty blower motor ground circuit wiring or connectors

Faulty blower motor resistor (manual temperature control)

Faulty blower motor power module (ATC)

Faulty blower motor switch

Faulty heater-A/C mode control switch

Faulty blower motor feed circuit wiring or connectors

Faulty blower motor.

Possible causes of the blower motor not operating in all speeds include:

Faulty fuse

Faulty blower motor switch

Faulty blower motor resistor (manual temperature control)

Faulty blower motor power module (ATC)

Faulty high speed blower motor relay (ATC)

Faulty ATC controller

Faulty blower motor circuit wiring or connectors.