jeep Workshop Repair Guides

Jeep Workshop Service and Repair Manuals

Expansion Valve|Specifications|Page 6120 > < Expansion Valve|Specifications|Page 6118
Page 1
background image

Expansion Valve: Description and Operation

The "H" valve type Thermal Expansion Valve (TXV) is located at the front of the heater-A/C housing between the liquid and suction lines and the
evaporator coil.

The expansion valve is a factory calibrated unit and cannot be adjusted or repaired. If faulty or damaged, the expansion valve must be replaced.

High-pressure, high temperature liquid refrigerant from the liquid line passes through the expansion valve orifice, converting it into a low-pressure, low-
temperature mixture of liquid and gas before it enters the evaporator coil. A temperature sensor in the expansion valve control head monitors the
temperature of the refrigerant leaving the evaporator coil throught the suction line, and adjusts the orifice size at the liquid line to let the proper amount
of refrigerant into the evaporator coil to meet the vehicle cooling requirements. Controlling the refrigerant flow through the evaporator ensures that none
of the refrigerant leaving the evaporator is still in a liquid state, which could damage the compressor.

Expansion Valve|Specifications|Page 6120 > < Expansion Valve|Specifications|Page 6118