Wagoneer L6-242 4.0L VIN M FI (1988)
Oxygen Sensor: Testing and Inspection
Disconnect the oxygen sensor electrical connector from the wiring harness, and connect an ohmmeter across terminals A and B of the sensors electrical
connector. Resistance value should be between 5 and 7 ohms. Replace the sensor if it gives an infinity reading.