Wagoneer L6-258 4.2L VIN C 2-bbl (1982)
Evaporative Check Valve: Description and Operation
Fig. 30 Liquid Check Valve, Externally Mounted Type
This valve contains a float and Viton needle assembly. Should liquid fuel enter the check valve, the float will rise and force the needle upward
closing the vent passage and preventing fuel from flowing through the valve. Two different design valves are used, one picks up vapors from the
lines while the other picks up vapors from the fuel tank. Both operate the same.
After passing through the check valve, the fuel vapor is routed forward through a vent line to the vapor storage canister in the engine compartment.