Defender 90 (LD) V8-4.0L (1997)
Blower Motor Resistor: Service and Repair
A/C
Remove
NOTE: Access below evaporator unit.
1. Loosen outer screw securing resistor unit to clamp.
2. Rotate resistor on motor.
3. Disconnect Lucars from resistor unit.
NOTE: Resistor wires: G, U, R and O
4. Remove screws securing resistor to clamp.
5. Remove resistor unit and clamp.
Refit
6. Position clamp over motor and place resistor, terminals downward, onto motor.
7. Fit screws and tighten inner screw only.
8. Fit Lucars to resistor unit, in correct sequence.
9. Rotate resistor to fitted position and tighten outer screw.
10. Carry out system test. Refer to: Testing and Inspection.