landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Operation - engine management > < Description - engine management|Page 409
Page 347
background image

ENGINE MANAGEMENT SYSTEM - V8

18-2-48 DESCRIPTION AND OPERATION

Cooling fan relay

The cooling fan relay is located in the engine compartment fuse box. It is a four pin normally open relay. The relay 
must be energised to drive the cooling fan.

The cooling fan is used to cool both the condenser in which the ATC refrigerant is held and the radiator. This fan is 
used especially when the engine is operating at excessively high temperatures. It is also used as a part of the ECM 
backup strategy if the ECT fails.

Input/Output
The ECM provides the earth for the relay coils to allow the relay contacts to close and the cooling fan motor to receive 
battery voltage. The ECM uses a transistor as a switch to generate an open circuit in the earth path of the relay 
windings.  When the ECM opens the earth path, the return spring in the relay will pull the contacts apart to shut down 
the cooling fan motor drive.

Input to the cooling fan relay switching contacts is via fuse 5 located in the engine compartment fuse box. The relay 
coils are supplied with battery voltage from the main relay, also located in the engine compartment fuse box. The earth 
path for the relay coils is via pin 31 of the ECM connector C0636. When the relay is energised the output from the 
switching contacts is directly to the cooling fan motor.

The cooling fan relay can fail in the following ways:

l

Relay open circuit.

l

Short circuit to vehicle battery supply.

l

Short circuit to vehicle earth.

l

Broken return spring.

In the event of a cooling fan relay failure, the cooling fan does not work.

Operation - engine management > < Description - engine management|Page 409