landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 14760 > < Diagram Information and Instructions|Page 14758
Page 24
background image

the short or back feed. If voltage is present at the power and also the ground sides of a circuit, current can not flow. The load device cannot function.

OPEN CIRCUIT VOLTAGE

Open Circuit Voltages

Now we read the voltage in the same circuit as above but with no current flowing because there is an open at point "X." The voltage at "A," "B," and "C"
will all be 12 volts positive.

Remember, there is no voltage drop across a resistor or load if there is no current flowing.

USING A VOLTMETER (DIRECT VOLTAGE DROP)

To check the same circuit to determine if a resistance exists within the conductor:
Connect a voltmeter between the ends of the conductor, the Positive (red) lead to the supply end, and the Negative (black) lead to the load end. Switch
on the current supply; a reading of approximately 0.1 volt would be an acceptable figure. A higher reading would confirm, as the ohmmeter does, that a
higher resistance than the natural resistance of the conductor exists.

You may be wondering how the voltmeter gives a reading under these conditions. All test instruments have resistance within their structure; in the case
of a voltmeter, that resistance is very high. In the application of the voltmeter as illustrated, the voltage in the circuit will take the least path of resistance,
that is the conductor.

If a resistance higher than the natural resistance exists within the conductor, then the voltage will divide to flow through both the conductor and the
voltmeter, with the meter then showing a higher reading.

USING AN OHMMETER (NO POWER)

If one wishes to check for resistance within the conductor, ensure that the supply is switched OFF or disconnected, then connect an ohmmeter between
the ends of the conductor and note the reading. In the case of a good conductor it should read approximately Zero (ohms). A higher reading would
confirm that an unwanted resistance exists.