Air Door Cable: Service and Repair

Air Duct Cable 

Remove
1. Release fascia centre louvre vent panel from its fitted position to gain access to rear of panel.
2. Open glove box, manoeuvre side springs through cut-outs and lower lid.

Air Direction 

Temperature

3. Set control fully clockwise.
4. Release outer cable from 2 clips on unit.
5. Release cable from stud on flap lever.
6. Remove control cable from control lever.
7. Set RH control fully clockwise, LH control fully anti-clockwise
8. Release outer cable from 2 clips on unit.
9. Release cable from stud on flap lever.

10. Remove control cable from control lever.

Refit
11. Reverse removal procedure. Check the satisfactory function of the controls before fitting louvre vent panel.