landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Fresh Air Mode|Page 11946 > < Diagram Information and Instructions|Page 11943
Page 1
background image

Blower Motor: Description and Operation
Fresh Air Mode

With the Ignition Switch (X134) in position II, battery voltage is applied to the Ignition Load Relay (K127). The relay is energised, applying battery
voltage to the Air Recirculation Solenoid In-Line Fuse (P138) and Air Recirculation Solenoid (K123). When the Air Supply Selector Switch is moved to
the Fresh Air position, ground is applied to the Air Recirculation Solenoid (K123). The solenoid now opens the fresh air intake flap allowing fresh air to
enter the vehicle cabin. When the fresh air intake flap has been fully opened, the microswitch inside the Air Recirculation Solenoid (K123) moves to the
Fresh Air position interrupting the ground supply. The solenoid now stops and remains in the Fresh Air position.

Fresh Air Mode|Page 11946 > < Diagram Information and Instructions|Page 11943