Discovery I (LJ) V8-4.0L (1996)
Evaporator Core: Service and Repair
Remove
WARNING: Wear eye and hand protection when disconnecting components containing refrigerant. Plug all exposed connections immediately.
1. Remove heater and cooler unit. See: Evaporator Case/Service and Repair
2. Disconnect 2 Lucar connectors from thermostat.
3. Position wiring aside.
4. Remove 2 screws securing heater pipe bracket and position pipes aside.
5. Remove 10 clips retaining upper and lower casings.
6. Remove 5 screws retaining upper casing.
7. Remove lower casing and evaporator.