landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Expansion Valve|Service and Repair|Page 12478 > < Diagram Information and Instructions|Page 12474
Page 1
background image

Expansion Valve: Service and Repair

Remove

WARNING: Wear eye and hand protection when disconnecting components containing refrigerant. Plug all expose  connections immediately.

1. Remove heater and cooler unit.  See: Evaporator Case/Service and Repair

2. Disconnect 2 Lucar connectors from thermostat.
3. Position wiring aside.
4. Remove 2 screws securing heater pipe bracket and position pipes aside.
5. Remove 10 clips retaining upper and lower casings.
6. Remove 5 screws retaining upper casing.
7. Remove lower casing and evaporator.

Expansion Valve|Service and Repair|Page 12478 > < Diagram Information and Instructions|Page 12474