landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Refrigerant Control Solenoid Valve > < Refrigerant|Capacity Specifications|Page 12549
Page 2
background image

CAUTION: The system must be evacuated immediately before recharging commences. Delay between evacuation and recharging is not
permitted.

5. Operate the refrigerant recharging system according to the manufacturer's instructions:-

Refrigerant to charge system is 0.90 kg (32 fl/oz) With rear air conditioning total charge is 1.15 kg (40 fl/oz)

6. If the full charge has not been accepted by the system, start the engine and run it at 1500 rev/min for a minimum of 2 minutes. Switch on the air

conditioning system, open the car windows, set the temperature control to cold and switch the blower to maximum speed.

7. Consult Refrigerant Station Manual for correct procedure to complete the charge.
8. Carry out the air conditioning system performance test.

Refrigerant Control Solenoid Valve > < Refrigerant|Capacity Specifications|Page 12549