landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

TEC861797 > < ECM Connectors - Water Contamination|Page 11333
Page 3
background image

The plenum water drains are round and approximately 1 inch in diameter.

8.

Check the water drains in the plenum to ensure that they are not blocked with sealant or debris, and clean as necessary.

9.

When servicing the GEMS ECM at any time ensure that the wire harnesses leading to the ECM are routed in such a way as to have a length that is
lower than the ECM connectors in order to form a "drip loop."

10.

Reinstall GEMS ECM and secure with nuts.

NOTE:

Always replace the GEMS ECM protective cover fir-tree fasteners with new ones (YOO3100PMA) to ensure proper positioning of the cover.

11.

Install GEMS ECM cover.

12.

Refer to Figure 1 and install fender seal MUC4177 along the fender flange, abutting the existing plenum seal.

TEC861797 > < ECM Connectors - Water Contamination|Page 11333