landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

ECU/ECM - Intermittent No Crank/No Start|Page 6353 > < ECM Connectors - Water Contamination|Page 6348
Page 1
background image

Technical Service Bulletin # TEC8616973

Date: 971126

ECU/ECM - Intermittent No Crank/No Start

No: 86/16/97/NAS

Ref: WSM section 86

* Issue: 3 *

Revisions are noted by asterisks.

Date: 11/26/97

PRIDE IV

6-12

Intermittent Failure of Engine to Start

AFFECTED VEHICLE RANGE:
DISCOVERY (LJ)

All GEMS Equipped

SITUATION:

ENGINE CRANKS BUT WILL NOT START OR INTERMITTENTLY WILL NOT CRANK

Intermittently the vehicle may not crank or crank and not start. Some or all of the following symptoms may be present:

^

The "Check Engine" light does not illuminate when the key is turned to position II (run).

^

A delay of 3 to 5 seconds between turning the key to position III (crank) and engine cranking.

^

After turning the key off (position I) then on again, the vehicle starts normally.

RESOLUTION:

* MODIFICATION OF THE IMMOBILIZATION STRATEGY *

The symptoms outlined indicate that the engine is temporarily immobilized due to a miscommunication between the security (10AS) ECU and GEMS
ECM.

The technician must inspect and verify that two circuits and six electrical terminals are in good condition and working correctly as outlined in the repair
instructions. When it is determined by the above electrical inspection that the fault is in the ECU, a security strategy modification can be performed to
install the most current security ECU configuration. Use TestBook and the "Discovery Security Configuration" compact disk.

NOTE:

The repairs outlined in this TIB are to be performed to resolve customer complaint of the symptoms described.

* TOOL INFORMATION: *

TestBook disk

DRG0ROBW
Discovery Security Configuration

WARRANTY CLAIMS:

86.77.89/36

Time 1.00 hrs.
Verify Electrical connections and Install Current Immobilization Strategy using TestBook.

ECU/ECM - Intermittent No Crank/No Start|Page 6353 > < ECM Connectors - Water Contamination|Page 6348