1.

Remove fir-tree fasteners from ECM cover and remove the cover (Figure 1).

CAUTION:

Whenever the connectors are removed from the GEMS ECM, care must be taken that the anti-backout devices remain in the harness
connectors.

2.

Remove the ECM connectors and examine for water intrusion or corrosion.

3.

Remove the two nuts securing GEMS ECM to body and remove.

* 4.

Install plastic plugs LRN236X1AH1 in holes in the inner fender behind ECM (Figure 2). *

* 5.

Replace grommet where the washer hose passes into the air intake plenum with grommet LRN2274-006 (Figure 3). *

6.

If the vehicle is equipped with unused heated windshield wiring, inspect the fit of the grommet for the heated windshield wire.

7.

If the windshield wire grommet does not seal well to the cable, replace the grommet as follows:

^

Pull the wire harness and grommet back into the intake plenum.

^

Insulate connectors with tape and secure removed harness to the main harness.

^

Ensure that the harness does not contact ground.

^

Install solid grommet AMR5619 into the hole in the plenum where the wire used to be.

NOTE: