landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Ventilation Switch > < Refrigerant Pressure Sensor / Switch, HVAC|Locations|Page 1691
Page 1
background image

Refrigerant Pressure Sensor / Switch: Service and Repair

Dual Pressure Switch 

Remove
1. Disconnect battery negative lead.
2. Recover refrigerant from system.See: Heating and Air Conditioning/Service and Repair

3. Disconnect multiplug from switch.
4. Unscrew switch from adapter. Use a second wrench to support adapter.

WARNING:  Wear eye and hand protection when disconnecting components containing refrigerant. Plug all exposed connections immediately.

5. Remove 'O' ring from switch.

Replace
6. Reverse removal procedure. Lubricate new 'O' ring with refrigerant oil and fit to switch.
7. Screw switch into adapter and tighten to 11 Nm.
8. Evacuate and recharge air conditioning system.See: Heating and Air Conditioning/Service and Repair 