landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

HO2S - Handling and Diagnostic Procedures|Page 2142 > < HO2S - Handling and Diagnostic Procedures|Page 2140
Page 4
background image

proceeding with test.

1.

Calibrate lead set for accurate voltage readings.

2.

Switch off A/C compressor.

3.

Set Uniscope red channel on ± 7 VDC and 32 ms.

4.

Back probe pin 33 of red 36 pin connector for bank B, or pin 34 for bank A sensors.

5.

Run engine to operating temperature (approx. 195°F) then heat engine and HO2S's fully by running engine 2-3 minutes at 2500 rpm. Let idle for 5
seconds but no more than 20 seconds.

6.

Push record on Uniscope.

7.

Rev the engine rapidly four to five times in 2 second intervals from idle to wide open throttle (do not exceed 300 rpm).

8.

Examine recording frame by frame. set cursor # 1 at maximum HO2S voltage and take a reading; record maximum voltage results. Set cursor # 2
on minimum HO2S voltage and record results.

9.

Measure rich-lean response times.

NOTE: Do not judge response times at the beginning of the record cycle (i.e. frames 1-3).

10.

Print screens using print icon on upper right corner of screen.

HO2S - Handling and Diagnostic Procedures|Page 2142 > < HO2S - Handling and Diagnostic Procedures|Page 2140