7. Apply High Formular Hylomar sealant to 4 longer bolt threads and fit bolts in position shown.
8. Fit remaining bolts and tighten progressively in a diagonal sequence to 46 Nm (34 ft. lbs.).
9. Place LRT-44-003/1 into pump housing, tighten screws to secure LRT-44-003/1 to input shaft.
10. Clamp a suitable steel base to converter housing flange.
11. Mount DTI gauge and position gauge probe onto LRT-44-003/1 and zero gauge.
12. Check that the axial end-float is between 0.2 to 0.4 mm (0.008 to 0.016 inch). If end-float in not within limits, replace existing thrust washer,
positioned at rear of intermediate plate, with a suitable thickness thrust washer to give the required end-float.
13. Remove DTI gauge and base plate.
14. Fit torque converter oil seal.