landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Extension Housing, M/T|Service and Repair|Page 3654 > < Extension Housing, M/T|Service and Repair|Page 3652
Page 3
background image

12. Remove reverse inhibitor shaft, cam and spring.
13. Remove 2 bolts and remove gate plate.

14. Remove reverse light switch and discard sealing washer.
15. Remove 2 bolts, remove oil cooler by-pass and discard 'O' rings.

Reassembly

1. Clean extension housing and mating faces.
2. Clean oil cooler by-pass.
3. Using new 'O' rings, fit oil cooler by-pass and tighten bolts to 15 Nm (11 ft. lbs.).
4. Using new sealing washer, fit reverse light switch and tighten to 24 Nm (17 ft. lbs.).
5. Fit reverse inhibitor spring and cam,
6. Clean threads of reverse inhibitor shaft and gate plate bolts.
7. Apply Loctite 290 to threads of reverse inhibitor shaft, fit and tighten shaft.
8. Apply Loctite 290 to threads of gate plate bolts.
9. Position gate plate and tighten bolts to 15 Nm (11 ft. lbs.).

10. Fit output shaft support bearing and oil pick-up ring. Align tag with centre of drain slot.
11. Fit layshaft support bearing.

12. Fit new output shaft oil seal using tool LRT-37 014.
13. Fit oil pick-up pipe with the off -set uppermost.
14. Lubricate oil pump recess with gearbox oil.
15. Lubricate a new 'O' ring with gearbox oil and fit to oil pump.
16. Locate oil pump in extension housing with word 'TOP' towards top of housing.
17. Align oil pump fixing screw holes and tap pump lightly around edges until it is fully in recess. Do not attempt to pull pump into recess using fixing

screws.

18. Fit Torx screws and tighten to 6 Nm (4.5 ft. lbs.).
19. Remove 2 slave bolts securing centre plate to gearbox casing.
20. Apply sealant, Part No. STC 3254 to gearbox casing face.
21. Position extension housing, align oil pump drive with layshaft.
22. Clean extension housing bolt threads.
23. Apply Loctite 290 to threads of extension housing bolts, fit bolts ensuring 2 longest bolts are in their original positions and tighten by diagonal

selection to 25 Nm (18 ft. lbs.).

24. Using new 'O' ring, fit interlock spool retainer and tighten bolt to 8 Nm (6 ft. lbs.).

Extension Housing, M/T|Service and Repair|Page 3654 > < Extension Housing, M/T|Service and Repair|Page 3652