landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Recall - Potential Roof Opening Panel Separation|Page 5491 > < Body - Roof Opening Panel Misaligned/Jammed|Page 5486
Page 1
background image

Sunroof / Moonroof Panel: All Technical Service Bulletins
Recall - Potential Roof Opening Panel Separation

No.: P009

Issue: 1

Date: 17 MAR 2008

SECTION: 501

RECALL: LR2 Roof Opening Panel Function

AFFECTED VEHICLE RANGE:

LR2 (LF)

VIN: 8H000212 - 8H087347
Model Year: 2008

CONDITION SUMMARY:

ROOF OPENING PANEL FUNCTION

Situation: 

A concern with the operation of the roof opening panel on LR2 vehicles has been identified where failure of either the left- or right-side roof opening
panel guide rail could cause the roof opening panel to become detached from its operating mechanism and bind. The operator may hear a cracking noise
if this condition occurs. If this condition occurs, the roof opening panel glass panel will remain attached to its frame, but further attempts to operate will
result in continued noise and abnormal operation due to the binding condition. If a vertical force is applied (for example: a customer manually aiding the
roof opening panel to close or wind lift) the glass panel can become fully detached from the vehicle. This unexpected separation of the roof openings
glass panel could possibly distract the driver, increasing the risk of a vehicle crash or loss of vehicle control. In addition, should the glass panel fully
detach from the vehicle it may impact nearby persons or objects resulting in personal injury and/or vehicle and property damage.

Action: 

Install two retention inserts as per the Repair Procedure outlined below.

PARTS

WARRANTY:

NOTE:

Always check DDW to verify that the vehicle is affected by this Recall prior to undertaking any repair. Some vehicle within the VIN-range will have
been repaired in port. DDW reflects only those vehicles affected and un-repaired.

NOTE:

Repair procedures are under constant review, and therefore times are subject to change; those quoted here must be taken as guidance only. Always
refer to DDW to obtain the latest repair time.

Warranty claims should be submitted quoting program code P009. This will result in payment of the stated time. As option codes are used, there is no
requirement for you to enter parts or labor; these are repeated here for information only.

REPAIR PROCEDURE

RAISING THE ROOF OPENING PANEL FOR ACCESS

Recall - Potential Roof Opening Panel Separation|Page 5491 > < Body - Roof Opening Panel Misaligned/Jammed|Page 5486