LR2 (LF) L6-3.2L (2008)
Evaporator Core: Service and Repair
Evaporator - LHD
Removal
NOTE: The removal of this component involves cutting an aperture in the evaporator housing wall and cutting through the high and low pressure A/C
lines. A service repair kit is supplied to cover this procedure.
1. Disconnect the battery ground cable.
2. Recover the A/C refrigerant.
3. Remove the plenum chamber panel.
4. If installed, remove the anti-theft alarm horn with integral battery.
CAUTION: Make sure that all openings are sealed. Use new blanking caps.
5. Disconnect the A/C pipes from the TXV.
7. Remove the RH floor console extension.
8. Remove the glove compartment.