Page 1
background image

 
 

Specifications  

Fluids and Capacities  
 

 
 

 
Capacity  
 

 
 
General Specifications  
 

Published : Feb 4, 2005

Item 

Specification 

* Anti-freeze 

Havoline Extended Life Coolant (XLC) or any ethylene glycol based anti-
freeze containing no methanol with only Organic Acid Technology (OAT) 
corrosion inhibitors 

Anti-freeze concentration - Will provide frost 
protection to -40°C (-40°F) 

50% 

Specific gravity of coolant at 20°C (68°F), to 
protect against frost down to -40°C (-40°F) 

1.068 

Amount of anti-freeze to use for 50% 
concentration: 

  

Without rear passenger compartment 
heater or fuel burning heater 

4.7 litres (8.25 pints) (4.9 US quarts) 

With rear passenger compartment heater 
but without fuel burning heater 

6.0 litres (10.6 pints) (6.4 US quarts) 

Without rear passenger compartment 
heater but with fuel burning heater 

5.1 litres (9.1 pints) (5.4 US quarts) 

With rear passenger compartment heater 
and fuel burning heater 

6.5 litres (11.5 pints) (6.9 US quarts) 

   CAUTION: * No other anti-freeze should be used with Havoline Extended Life Coolant. 

Item 

Capacity 

Without rear passenger compartment heater or fuel burning heater 

9.4 litres (16.5 pints) (9.9 US quarts) 

With rear passenger compartment heater but without fuel burning heater 12.15 litres (21.4 pints) (12.8 US quarts)

Without rear passenger compartment heater but with fuel burning heater 10.35 litres (18.2 pints) (10.9 US pints) 

With rear passenger compartment heater and fuel burning heater 

13.1 litres (23.0 pints) (13.8 US quarts) 

Item 

Specification 

Cooling system type  Pressurised, thermostatically controlled with remote header tank

Radiator 

Cross flow with integral transmission fluid and charge air coolers

Expansion tank 

Remote - fitted with a bleed screw and low coolant level sensor 

Pressure cap rating  110 kPa (1.1 bar) (16 lbf/in²) 

Thermostat: 

  

Starts to open 

88° C (190° F) 

Fully open 

95° C (203° F) 

Cooling fan 

Engine driven, viscous coupled with electronic control 

Cooling fan diameter  500 mm (19.6 in) 

Direction of rotation  Clockwise when viewed from front of engine 

Coolant pump 

Centrifugal flow impellor, belt driven from crankshaft 