LR3/Disco 3
The PCV is a variable position solenoid valve electronically controlled by the ECM. The PCV is located between the HP
pumping elements and the HP outlet connection. The PCV regulates the amount of fuel pressure in the fuel rails and is
controlled by the ECM. When there is no signal to the PCV the valve is open, therefore no rail pressure can be generated.
High Pressure Fuel Flow
Item Part Number
Description
A
-
LP fuel supply
B
-
Fuel supply to the HP pumping elements
C
-
HP outlet connection to the HP diverter rail
D
-
LP fuel return (spill)
1
-
LP side of ITP
2
-
ITP pressure relief valve