landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Positive Crankcase Ventilation Removal > < Description And Operations|Page 1509
Page 1
background image

 
 

Exhaust Gas Recirculation (EGR) Valve (17.45.01)  

Removal  

 

 

 

 

Installation  

 

 

 

Published : May 17, 2004

1 . 

  

Disconnect the battery ground cable. For additional information, refer to 

Specifications

 (Section 414-

00 Charging System - General Information) 

2 . 

  Disconnect the EGR valve electrical connector.

3 . 

  Release the clips and disconnect the hoses from the EGR valve cooler. 

  

Position an absorbent cloth to collect fluid spillage. 

  

Clamp the EGR coolant hoses to minimize coolant loss. 

4 . 

  Remove the EGR valve. 

  

Remove the 2 bolts from the EGR cooler valve body.

1 . 

  To install, reverse the removal procedure. 

  

Clean the component mating faces.

  

Tighten the bolts to 10 Nm (7 lb.ft). 

2 . 

  

Connect the battery ground cable. For additional information, refer to 

Specifications

 (Section 414-00 

Charging System - General Information) 

3 . 

  Check and top up the coolant.

Positive Crankcase Ventilation Removal > < Description And Operations|Page 1509