LR3/Disco 3
Air Cleaner (19.10.01)
Removal
Installation
Published : Apr 21, 2004
1 .
Disconnect the battery ground cable. For additional information, refer to
Specifications
(Section 414-
00)
2 .
Release the air cleaner intake pipe.
Loosen the clip.
3 .
Disconnect the mass air flow (MAF) sensor electrical connector.
4 .
Remove the air cleaner assembly.
1 .
NOTE :
When installing the air cleaner, make sure the locating pegs fit securely into the grommets.
To install, reverse the removal procedure.