LR3 (LA) V6-4.0L (2006)
Alternator: Service and Repair
Generator
Serive Repair No - 86.10.02
Removal
1. Disconnect the battery ground cable.
2. Remove the accessory drive belt.
3. Disconnect the generator electrical connectors.
^
Release the gaiter, remove the nut and disconnect the cable.
^
Disconnect the electrical connector.
4. Remove the generator. Remove the 3 bolts.
Installation
CAUTION: Tighten the bolts in the sequence shown.
1. Install the generator.
^
Clean the component mating faces.
^
Tighten the bolts to 45 Nm (33 ft. lbs.).
2. Connect the generator electrical connectors.
^
Tighten the nut to 10 Nm (7 ft. lbs.).
^
Connect and secure the electrical connector.
3. Install the accessory drive belt.
4. Connect the battery ground cable.