landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Refrigerant Oil > < Refrigerant|Capacity Specifications|Page 6606
Page 2
background image

permitted.

2. Close valves on refrigerant station.
3. Close valve on oil charger.
4. Disconnect yellow hose from refrigerant station.
5. Remove lid from oil charger.
6. Pour same quantity of refrigerant oil into oil charger as collected during recovery. If the following components have been removed, add the

following additional quantity of lubricating oil:
-

Condenser = 30 cubic centimeter.

-

Desiccant bag = 30 cubic centimeter.

-

Evaporator = 20 cubic centimeter.

-

Pipe/hose= 10 cubic centimeter.

7. Fit lid to oil charger.
8. Connect yellow hose to refrigerant station.
9. Open valve on oil charger.

10. Move pointer on refrigerant gauge to mark position of refrigerant drop.
11. Slowly open correct valve on refrigerant station and allow vacuum to pull refrigerant into system.
12. Close valve on refrigerant station when correct amount of refrigerant has been drawn into air conditioning system.
13. Turn Main switch to 'OFF'.
14. Close valves on connectors.
15. Disconnect high and low pressure connectors.

Refrigerant Oil > < Refrigerant|Capacity Specifications|Page 6606