landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Lighting - Condensation in Tail Lamps|Page 9085 > < Lighting - Condensation in Tail Lamp Assemblies|Page 9080
Page 1
background image

Tail Lamp: All Technical Service Bulletins
Lighting - Condensation in Tail Lamps

No: 86/06/05/NAS
FGN 417-01
Ref:
Issue: 1
Date: 21 July 2005

Water Ingress into Tail Lamps

AFFECTED VEHICLE RANGE:
New Range Rover (LM) 3A101020 to 5A186201

SITUATION:

CONDENSATION OR WATER INGRESS INTO TAIL LAMPS

A customer may report a concern of misting evident on the inside of the tail lamp lens. The misting is generally caused by natural condensation and can
be expected under certain atmospheric conditions.
However, water can also enter the lamp via the breather tube under extreme conditions.

RESOLUTION:

INSPECT FOR WATER INGRESS AND CORRECT IF INDICATED

Upon customer complaint of tail lamp water ingress refer to the Service Procedure detailed in this bulletin.

PARTS INFORMATION:

XFB500360..............Lamp assembly RH rear NAS Qty 1
XFB500370..............Lamp assembly LH rear NAS Qty 1

DDW WARRANTY CLAIMS:

NOTE

Repair procedures are under constant review, and therefore times are subject to change; those quoted here must be taken as guidance only. Always
refer to DDW to obtain the latest repair time. 

DDW requires the use of causal part numbers. Labor only claims must show the causal part number with a quantity of zero.

Normal warranty policy and procedures apply.

REPAIR PROCEDURE

INSPECT FOR CONDENSATION

NOTE

Normal condensation is a natural process. Range Rover tail lamps are vented to alleviate changes in pressure through a breather vent. 

^

Atmospheric air contains water vapor referred to as humidity. When this air enters the tail lamp under any circumstance, there is a possibility
that condensation can occur if the temperature is cold enough.

^

When normal condensation occurs, a thin film of mist can form on the inside surface of the plastic lens. The thin mist will clear and exit
through the vents during normal lamp operation.

1.

If condensation is reported, determine if it dissipates during a thirty minute period of normal tail lamp operation as the lamp heats up.

Lighting - Condensation in Tail Lamps|Page 9085 > < Lighting - Condensation in Tail Lamp Assemblies|Page 9080