landrover Workshop Repair Guides

Land Rover Workshop Service and Repair Manuals

Evaporator Case|Service and Repair|Page 9115 > < A/C System - R 134A Conversion Kit|Page 9111
Page 1
background image

Evaporator Case: Service and Repair

WARNING:  Wear eye and hand protection when disconnecting components containing refrigerant. Plug all exposed connections immediately.

REMOVE

1. Open the hood and connect the gauge set.
2. Discharge the system.
3. Disconnect the battery negative lead.
4. Disconnect the evaporator hoses from the compressor and the receiver drier. Use a second wrench to support the hose adaptors.

Mounting Screws

5. Working underneath the dash unit remove the two screws securing the blower closing panel. Slide the panel out of the two lower retaining clips.
6. Remove the Nyloc nut and washer from the evaporator case mounting bracket.

Mounting Nuts

7. Remove the two Nyloc nuts securing both center dash panel and evaporator case mounting bracket.

Mounting Scews

Evaporator Case|Service and Repair|Page 9115 > < A/C System - R 134A Conversion Kit|Page 9111