Range Rover County LWB (LH) V8-4.2L (1993)
Pick-Up Coil: Adjustments
Pick-up Gap Adjustment
1. The air gap between the pick-up limb and reluctor teeth must be set within the specified limits, using a non-ferrous feeler gauge.
2. If adjustment is necessary, slacken the two barrel nuts to set the air gap to 0.008-0.014 in (0.20-0.35 mm).