lincoln Workshop Repair Guides

Lincoln Workshop Service and Repair Manuals

Module Configuration|Page 4460 > < Module Configuration|Page 4458
Page 2
background image

The navigation module is located behind the rear seat under the carpet. The navigation module is on the SCP communications network. The navigation
module controls the global positioning system on the vehicle.

Principles of Operation (How Does It Work?)

PRINCIPLES OF OPERATION

The vehicle has three module communications networks: the standard corporate protocol (SCP), which is an unshielded twisted pair cable (data bus plus,
(Circuit 914 [TN/OG]) and data bus minus, (Circuit 915 [PK/LB]), the single wire circuit 693 (OG) universal asynchronous receiver-transmitter (UART)
based protocol (UBP) communications network and the International standards organization (ISO) 9141 communications network, which is a single wire
network (Circuit 70 [LB/WH]). Both networks are connected to the data link connector (DLC). This makes diagnosis and testing of these systems easier
by allowing one smart tester to be able to diagnose and control any module on the two networks from one connector. The DLC can be found under the
Instrument panel between the steering column and the radio.

The SCP communications network will remain operational even with the severing of one of the bus wires. Communications will also continue if one of
the bus wires is shorted to ground or voltage, or if some but not all termination resistors are lost.

The ISO 9141 communications network does not permit intermodule communication. When the diagnostic tool communicates to modules on the ISO
9141 communication network, the diagnostic tool must ask for all information; the modules cannot initiate communications.

The ISO 9141 communications network will not function, if the wire is shorted to ground or battery voltage. Also, if one of the modules on the ISO 9141
communications network loses power or shorts internally, communications to that module will fail.

The UBP communications network will not function if the wire is shorted to ground or voltage. The UBP is different from the ISO communication
network in that it allows intermodule communication.

Module Configuration|Page 4460 > < Module Configuration|Page 4458