Power Mirror Switch: Testing and Inspection
Specific Switch Test

Measure the resistance between the following terminals while pressing each requested switch:

Switch 

 Terminals

Memory switch no.1 

 6 and 4

Memory switch no.2 

 6 and 3

Memory set switch 

 6 and 1

The resistance should be less than 5 ohms for each switch position.

If the resistance is less than 5 ohms for each switch, return to the calling pinpoint test; otherwise, INSTALL a new switch.

Memory Set Switch LED Circuit

NOTE:  Refer to Multimeter Users Manual for testing diodes.

Check the diode in the Light Emitting Diode (LED) circuit for continuity.

Switch 

 Terminals

Memory Set LED 

 8 and 9

With the positive lead connected the Terminal 8 and the negative lead connected to Terminal 9, the meter should read greater than 0.3 volts. Reversing
the leads, the meter should read OL. If not, INSTALL a new switch.