Accumulator HVAC: Service and Repair

REMOVAL

1. Disconnect the battery ground cable.
2. Recover the refrigerant.

3. Remove the junction block splash shield.

4. Disconnect the cable ends.

5. Remove the junction block bracket.

1

Disengage the connector.

2

Remove the screws.

3

Remove the junction block bracket.

6. Disconnect the A/C cycling switch electrical connector.

Accumulator HVAC|Specifications|Page 7337 > < Accumulator HVAC|Specifications|Page 7335