lincoln Workshop Repair Guides

Lincoln Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 11093 > < Diagram Information and Instructions|Page 11090
Page 1
background image

Clock: Initial Inspection and Diagnostic Overview

1. Verify the customer concern by operating the electric clock.
2. Visually inspect for obvious signs of mechanical and/or electrical damage using the Visual Inspection Chart.

VISUAL INSPECTION CHART

Mechanical
^

Damaged electric clock

Electrical
^

Blown fuse:
-

I/P Fuse 2 (5A)

-

I/P Fuse 8 (5A)

-

I/P Fuse 18 (5A)

^

Damaged wire(s)

^

Loose or corroded connectors

3. If an obvious cause for an observed or reported malfunction is found, correct the cause (if possible) before proceeding to the next step.
4. If the fault is not visually evident, verify the symptom and See: Symptom Related Diagnostic Procedures

Initial Inspection and Diagnostic Overview|Page 11093 > < Diagram Information and Instructions|Page 11090