lincoln Workshop Repair Guides

Lincoln Workshop Service and Repair Manuals

Cleaning and Inspection|Page 5563 > < Diagnosis|Page 5560
Page 1
background image

Torque Converter: Service and Repair
Cleaning and Inspection

1. If the torque converter is being replaced, continue with sub-step 2 of Step 2.
2. If the torque converter is not being replaced the following procedures must be performed:

1

The torque converter must be thoroughly cleaned.
-

Torque converters with drain plugs may be cleaned by using the Torque Converter/Oil Cooler Cleaner.

-

Torque converters without drain plugs may be cleaned by hand. Partially fill the torque converter using only the recommended
transmission fluid for the applicable transmission. Hand-agitate the torque converter and then thoroughly drain the fluid. Refill the torque
converter with new fluid specified for the transmission, and reinstall.

2

The in-tank and auxiliary coolers must be thoroughly cleaned by forward and backward flushing procedure.

3

The cooler lines must be thoroughly cleaned by backward and forward flushing.

4

All Cooler Bypass Valves (CBV), if equipped, must be thoroughly cleaned.

5

Perform the Transmission Fluid Cooler Flow Test.

6

If the transmission cooling system fails the Transmission Fluid Cooler Flow Test, the fluid cooler, cooler bypass valve, and/or cooler lines
must be replaced.

7

If the coolers or cooler by-pass valve are to be replaced use only factory-approved service parts.

Cleaning and Inspection|Page 5563 > < Diagnosis|Page 5560