lincoln Workshop Repair Guides

Lincoln Workshop Service and Repair Manuals

Accumulator HVAC|Description and Operation|Page 4502 > < Accumulator HVAC|Description and Operation
Page 1
background image

Accumulator HVAC: Service and Repair

SUCTION ACCUMULATOR

Removal and Installation

NOTE:  Installation of a new suction accumulator is not required when repairing the A/C system, except when there is physical evidence of
contamination from a failed A/C compressor or damage to the suction accumulator. Damage to the suction accumulator includes leaks in the suction
accumulator, physical damage to the suction accumulator shell or desiccant, or moisture contamination. Moisture contamination results only from a
complete loss of refrigerant and equalization of the refrigerant system pressure with atmospheric pressure for a period longer than one hour. If even a
slight amount of positive refrigerant pressure is present in the system before repairs are carried out, a new suction accumulator should not be installed.

1. With the vehicle in NEUTRAL, position it on a hoist.
2. Recover the refrigerant.
3. Disconnect the suction accumulator outlet fitting.

-

Discard the O-ring seals.

4. Disconnect the suction accumulator inlet fitting.

-

Discard the O-ring seals.

5. Disconnect the A/C cycling switch electrical connector.
6. Remove the 3 suction accumulator bolts.

-

To install, tighten to 15 Nm (11 lb-ft).

7. Remove the suction accumulator.
8. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

Accumulator HVAC|Description and Operation|Page 4502 > < Accumulator HVAC|Description and Operation